T8600D, T8601D AND T8602D CHRONOTHERM ® IV DELUXE PROGRAMMABLE THERMOSTATS 68-0164—1 2 ORDERING INFORMATION When purchasing replacement and modernization products from your TRADELINE® wholesaler or distributor, refer to the TRADELINE® Catalog or price sheets for complete ordering number. View and Download Honeywell Chronotherm IV T8600D installation instructions manual online. Deluxe Programmable Thermostats. Chronotherm IV T8600D Thermostat pdf manual download. T8602D CHRONOTHERM® IV PROGRAMMABLE THERMOSTATS 69-1510-4 2 Fig. Typical location of thermostat. Mounting the wallplate. WIRING All wiring must comply with local electrical codes and ordinances. Refer to Fig. 3 through 6 for typical hookups. A letter code is located near each terminal for identification. CAUTION Electrical Hazard. Honeywell Chronotherm Iv Plus User Manual Honeywell Chronotherm III Heat Cool Thermostat T8601c 1047 T8601c1047 Digital, Honeywell Chronotherm Iv Plus User Manual Free eBook Download. Honeywell thermostat chronotherm iv plus manual. Guide to increase orgasms bd p1400 user manual wow free horde levelling guide samsung 76df.
T8602D CHRONOTHERM® IV PROGRAMMABLE THERMOSTATS
69-1510-4
6
Table 3. Thermostat Installer Setup Options.
Select
Installer Setup
Number (Press
Time
∆ key to
change)
Factory Setting
Other Choices
(Press or key to change)
Actual
Setting
Display
Description
Display
Description
Not Used.
1
—
—
—
—
—
Fan
operation.
2
(Number 2 must
be set to 1 to
extend fan
operation.)
0
Conventional
applications
where
equipment
controls fan
operation in heat
mode.
1
Heat pump or electric heat
applications where
thermostat controls fan
operation in heat mode.
Not Used.
3
—
—
—
—
—
Heating cycle
rate.
4
6
6—6 cph used
for conventional
heat.
Honeywell Chronotherm Iv Plus Manual
1, 3, or
9
1—1 cph used for radiant
floor heat, gravity
system.
3—3 cph used for hot
water systems or high
efficiency furnaces.
9—9 cph used for electric
heat systems.
Not Used.
5 thru 11
—
—
—
—
—
System
setting
adjustment
12
1
Manual
changeover
0 or 2
0—Auto changeover
2—Auto only
Adaptive
Intelligent
Recovery™
control.
13
1
Conventional
recovery
(system starts
recovery at
programmed
time).
Adaptive Intelligent
Recovery™ control is
activated (system starts
early so setpoint is
reached by start of
program period).
—
Not Used.
14 thru 15
—
—
—
—
—
Clock format.
16
0
12-hour clock
format.
Honeywell Chronotherm Iv Plus User's Manual Instructions
1
24-hour clock format.
Not Used.
17 thru 23
—
—
—
—
—
Outdoor
temperature
display
(select
models).
24
0
No outdoor
temperature is
displayed.
1
Outdoor temperature is
displayed. Needs a
C7089B1000 Outdoor
Temperature Sensor to
operate.
Not Used.
25 thru 32
—
—
—
—
—
Minimum off
time for the
compressor.
33
5
5 minute
minimum off time
for the
compressor.
0 thru 4
Minimum number of
minutes (0 thru 5) the
compressor will be off
between calls for the
compressor.
Temperature
range stops
in heating.
34
32.0
Highest setting
for heating
setpoint.
4.5 to
31.5
Temperature range (0.5°C
increments) of heating
setpoint settings.
Temperature
range stops
in cooling.
35
7.0
Lowest setting
for cooling
setpoint.
7.5 to
37.0
Temperature range (0.5°C
increments) of cooling
setpoint settings.