T8600D, T8601D AND T8602D CHRONOTHERM ® IV DELUXE PROGRAMMABLE THERMOSTATS 68-0164—1 2 ORDERING INFORMATION When purchasing replacement and modernization products from your TRADELINE® wholesaler or distributor, refer to the TRADELINE® Catalog or price sheets for complete ordering number. View and Download Honeywell Chronotherm IV T8600D installation instructions manual online. Deluxe Programmable Thermostats. Chronotherm IV T8600D Thermostat pdf manual download. T8602D CHRONOTHERM® IV PROGRAMMABLE THERMOSTATS 69-1510-4 2 Fig. Typical location of thermostat. Mounting the wallplate. WIRING All wiring must comply with local electrical codes and ordinances. Refer to Fig. 3 through 6 for typical hookups. A letter code is located near each terminal for identification. CAUTION Electrical Hazard. Honeywell Chronotherm Iv Plus User Manual Honeywell Chronotherm III Heat Cool Thermostat T8601c 1047 T8601c1047 Digital, Honeywell Chronotherm Iv Plus User Manual Free eBook Download. Honeywell thermostat chronotherm iv plus manual. Guide to increase orgasms bd p1400 user manual wow free horde levelling guide samsung 76df.

Advertising

T8602D CHRONOTHERM® IV PROGRAMMABLE THERMOSTATS

69-1510-4

6

Table 3. Thermostat Installer Setup Options.

Select

Installer Setup

Number (Press

Time

key to

change)

Factory Setting

Other Choices

(Press or key to change)

Actual

Setting

Display

Description

Display

Description

Not Used.

1

Fan
operation.

2

(Number 2 must
be set to 1 to
extend fan
operation.)

0

Conventional
applications
where
equipment
controls fan
operation in heat
mode.

1

Heat pump or electric heat
applications where
thermostat controls fan
operation in heat mode.

Not Used.

3

Heating cycle
rate.

4

6

6—6 cph used
for conventional
heat.

Honeywell Chronotherm Iv Plus Manual

1, 3, or
9

1—1 cph used for radiant

floor heat, gravity
system.

3—3 cph used for hot

water systems or high
efficiency furnaces.

9—9 cph used for electric

heat systems.

Not Used.

5 thru 11

System
setting
adjustment

12

1

Manual

changeover

0 or 2

0—Auto changeover
2—Auto only

Adaptive
Intelligent
Recovery™
control.

13

1

Conventional
recovery
(system starts
recovery at
programmed
time).

Adaptive Intelligent
Recovery™ control is
activated (system starts
early so setpoint is
reached by start of
program period).

Not Used.

14 thru 15

Clock format.

16

0

12-hour clock
format.

Honeywell Chronotherm Iv Plus User's Manual Instructions

1

24-hour clock format.

Not Used.

17 thru 23

Outdoor
temperature
display
(select
models).

24

0

No outdoor
temperature is
displayed.

1

Outdoor temperature is
displayed. Needs a
C7089B1000 Outdoor
Temperature Sensor to
operate.

Not Used.

25 thru 32

Minimum off
time for the
compressor.

33

5

5 minute
minimum off time
for the
compressor.

0 thru 4

Users

Minimum number of
minutes (0 thru 5) the
compressor will be off
between calls for the
compressor.

Temperature
range stops
in heating.

34

32.0

Highest setting
for heating
setpoint.

4.5 to
31.5

Temperature range (0.5°C
increments) of heating
setpoint settings.

Temperature
range stops
in cooling.

35

7.0

Lowest setting
for cooling
setpoint.

7.5 to
37.0

Temperature range (0.5°C
increments) of cooling
setpoint settings.

Not Used.

36

Advertising
Popular Brands
Popular manuals
Copyright © 2003 Honeywell • • All Rights Reserved

Honeywell Chronotherm Iv Plus Troubleshooting

69-1670
®
Deluxe Programmable
APPLICATION
®
IV Deluxe Programmable Thermostat provides electronic control of 24 Vac single-stage
heating and cooling systems or 750 mV heating system. Refer to Table 1 for a general description of the thermostat. All
Table 1. Description of T8602 Thermostats.
If this control is replacing a control that contains
control in the trash. Dispose of properly.
for instructions regarding recycling and the
INSTALLATION
1.Read these instructions carefully. Failure to follow
a hazardous condition.
2.Check the ratings given in the instructions and on
the product to make sure the product is suitable for
3.Installer must be a trained, experienced service
4.After completing installation, use these instructions
Location
Install the thermostat about 5 ft (1.5m) above the floor in
an area with good air circulation at average temperature.
Do not install the thermostat where it can be affected by:
—drafts, or dead spots behind doors and in corners.
—radiant heat from sun or appliances.
—unheated (uncooled) areas such as an outside wall
Wallplate Installation
The thermostat can be mounted horizontally on the wall
or on a 2 in. x 4 in. (50.8 mm x 101.6 mm) wiring box.
Position wallplate horizontally on the wall or on a
T8602SystemChangeoverSystem Selection

Honeywell Chronotherm Iv Plus T8601d2019 Manual

SelectionComments

Honeywell Chronotherm Iv Plus Manual T8611

CHeat-CoolManualHeat-Off-CoolOn-AutoSystem and fan selections are made on

Honeywell Chronotherm Iv Plus User Manual

Summary of content (12 pages)