Melting Point Meter M5000 For powdery substances with a melting point up to 400 °C. A fan cooling allows fast measurements in every range of temperature. The display provides a clearly-arranged readout of all important measuring data.-Fully automatic measuring instrument-Digital temperature control via LCD-display-Sealed keyboard for easy cleaning. The modern melting point meter is faster and more accurate, providing reproducible results which do not rely on the skill of the individual operator and which can be printed for a permanent record. Digital control means that the sample is heated, the melting point recorded, and the apparatus cooled ready for the next sample is just a few. Figure 10: Chemical Injection Point Upstream of Meter If a meter must be installed downstream of a chemical injection connection, the distance between the meter and the injection point should be between 50 and 100 feet (15 and 30 meters). The distance must be long enough to allow the water or chemical solution to reach the meter in a complete. User Manual TROUBLESHOOTING The M5000 mag meter is designed for many years of optimal performance However, should it malfunction, there are certain things that we recommend you check before contacting our Technical Support department or your local Badger Meter Representative. For general-purpose detection in a standalone package, the ModMAG M-Series® M5000 Electromagnetic Flow Meter is the ideal solution for remote applications. The meter provides accurate measurements designed for potable water apps. The M5000 features a user.

Density Meters for semi-automatic sample supply. High efficiency and special suitability for hazardous substances.

  1. Melting Point adalah alat yang di gunakan untuk mengukur titik lebur atau titik leleh dari suatu senyawa yang akan di analisa. Dalam hal ini Melting Point Merek Kruss menawarkan tiga model dalam seri Melting Point Meter, untuk menganalisis titik leleh zat tepung/powder,yaitu: M5000,KSP1N dan KSP1D.
  2. OptiMelt is the only melting point apparatus that can also be used as a general-purpose digital thermometer and timer. In between melting point determinations, OptiMelt may be used with a Pt RTD to measure and log temperatures around the lab. Three built-in timers are also available to keep track of timed events during experiments.

If you need discussion about this product, please click “Find Solution”. Or click the “Order Now” to buy now.

Specification

High efficiency and special suitability for hazardous substances

Melting Point Meter M5000 User Manual Pdf

In case of low-viscous to slightly viscous samples, it is possible to perform a semi-automatic sample supply and cleaning of the U-tube oscillator using a peristaltic pump. This means higher efficiency and more safety if aggressive or harmful substances are analysed. It also improves the reproducibilityof the measurement results.

Melting point meter m5000 user manual diagram
  • Drying unit and peristaltic pump with high chemical resistance
  • Intuitive operation via touch-screen display
  • Easy, menu-driven adjustment
  • Pre-defined scales such as density, relative density, brix, alcohol and sulfuric acid concentration
  • Compliance with GMP/GLP, 21 CFR Part 11, pharmacopoeias (USP, BP, JP, Ph. Eur.), FDA, ISO, HACCP, OIML, ASTM, ICUMSA, NIST

Typical applications

A comprehensive quality assurance covering the entire production process is a must in any industrial sector. Density measurements are frequently used for this purpose, especially in the pharmaceutical, chemical, petrochemical as well as the food and beverage industry. They allow the manufacturer to analyse raw materials, semi-finished and finished products as well as the manufacturing steps in terms of a number of factors.

Density can be used to identify substances, to determine their quality or purity and to measure their concentration in binary or quasi-binary mixtures. Substance conversions and reaction dynamics can also be inferred from it. In combination with other methods such as refractometry that measures the refractive index of substances, the density measurement allows you to make precise statements about the quality of each step of the production process.

Density meters based on the oscillating U-tube method are characterized by high ease of use and are therefore used in particular for continuous density measurement and for rapid routine measurements with larger numbers of samples in laboratories.

Compliance with national and international standards

A big advantage of normalized measurements is the comparability of the measurement results. Many international standards and guidelines recommend density meters for specific measuring tasks as suitable measuring instruments. The requirements for the measuring devices, such as measuring accuracy and measuring temperature, are dependent on the respective measuring task and defined in each standard. We have compiled for you an overview of all known standards and guidelines, which refer to the density measurement.

  • American Society for Testing and Materials (ASTM)
  • Hazard Analysis and Critical Control Points (HACCP)
  • International Organization of Legal Metrology (OIML)
  • National Institute of Standards and Technology (NIST)
  • International Commission on Uniform Methods of Sugar Analysis (ICUMSA)
  • European Pharmacopoeia (Ph. Eur.)
  • United States Pharmacopeia (USP)

Density measurement of liquids, emulsions and pastes

Thanks to the chemical-resistant sample carrying parts made of borosilicate glass and PTFE, our density meters are suitable for almost all liquids, emulsions and pastes.

Melting Point Meter M5000 User Manual Diagram

The sample is administered manually via syringe, semi-automatically via peristaltic pump or fully automatically via autosampler. High-viscosity samples are usually supplied by syringe, low to light viscous can also be supplied by means of peristaltic pump and autosampler. For every method of operation and every kind of sample, we have suitable density meter sets available that contain all the necessary accessories, from tubing sets to filling spouts and adapters to splash guards for the manual supply of aggressive substances.

In the following table we have compiled an overview of typical samples from our customers. Most samples were measured with an accuracy of 3 decimal places and at 20 ° C, deviations are indicated. The listed readings are not specifications.

MODELDS7700DS7800
MAIN SPECIFICATIONS
SCALESDensity [g/cm³]
Relative Density
Brix [%Brix]
Concentration of alcohol [vol%]
Concentration of sulphuric acid [wt%]
User-defined
MEASUREMENT RANGE0–3 g/cm³
ACCURACY±0.001 g/cm³±0.0001 g/cm³
MEASUREMENT PERIODTypically 1–3 minutes including temperature control
SAMPLE VOLUME IN CASE OF MANUAL INJECTION0,9 ml
AMBIENT TEMPERATURE10–40 °C
TEMPERATURE RANGE10–40 °C
TEMPERATURE RANGE±0.02 °C
METHODSA practically unlimited number of methods can be set
ADJUSTMENTAutomatic (menu-driven), with dried air and distilled water
CONTENT SET 3
DS7700-3/DS7800-3Drying unit with 3/2-way valve DS7060
Peristaltic pump
Tygon tube set for use with drying unit: Suction tube, drain tube, air tube, waste tube, tube connections Luer
Tube set for peristaltic pump: TPE pump tubes, PTFE tube connections (olive),
Luer nozzles
Luer syringes
PE waste container

Melting Point Meter for Semi-Automatic Measurements. The M3000 provides fast and easy examination of powdery substances with a melting point up to 360°C.

Melting point meter for automatic measurements. The M5000 provides fast, easy and automatic examination of powdery substances with a melting point up to 400 °C.

Density meters for manual sample supply Set 1 / Set 2. The right decision for low sample volumes.

Density meters for semi-automatic sample supply Set 3. High efficiency and special suitability for hazardous substances.

Manual

Density Meters DS7800 for Full-Automatic Sample Supply(Set 4 / Set 5). Fully automatic execution of the entire measuring process.

Digital Refractometers without Temperature Control. Specialists for sugar containing solution.

Digital Refractometers with Peltier Temperature Control. Allrounder for measuring all liquid and pastes.

Digital Refractometers with Automation. An optional solution for high sample volume.

Abbe Refractometer Analog(AR4) – Refractive index and % Brix can be measured and read via an eyepiece.

Digital Abbe refractometer (AR2008) – Refractive index and % Brix can be measured and displayed digitally.

Digital Handheld Refractometers DR101-60, DR201-95 and DR301-95. Digital on-site measurements at the touch of a button.

The M-Series® Mag Meter model M5000 detector is the result of years of research and field use in electromagnetic flow meters. Based on Faraday's Law of Induction, these battery powered meters can measure well water, wastewater, reclaimed water, chemicals, pharmaceuticals, and bi-directional flow applications that have minimal electrical conductivity.

Designed, developed and manufactured under strict quality standards, the M-Series meter features sophisticated, processorbased signal conversion with accuracies of ±0.50%. The wide selection of liner and electrode materials helps ensure maximum compatibility and minimum maintenance over a long operating period.

Because of its inherent advantages over other more conventional technologies, this meter can be used in the majority of industrial flow applications. Whether the fluid is water, highly corrosive, very viscous, contains a moderate amount of solids, or requires special handling, this meter accurately measures fluid flow. Today, magnetic meters are successfully used in industries including pharmaceutical, water and wastewater, and chemical.

Melting Point Meter M5000 User Manual Download

Applications for the Badger Meter M5000 Mag Flow Meter:

Melting Point Meter M5000 User Manual Guide

  • Water and Wastewater
  • Well Water and Reclaimed Water
  • Bi-directional flow applicaations
  • Food and Beverage