Pro 96 Manual Download

Win500 PRO-96 import: if Win500 can't determine whether an imported TSYS is 'MOT 800/900' vs. 'P25' based on the PRO-96 data, it will prompt you to select the type. Remote Client Version 1.04 2008.01.16 09:05 (GMT -0800) Added redundant Scan, Man, and Pause buttons to the right of the LCD. OWNER’S MANUAL — Please read before using this equipment. PRO-96 Digital Trunking Scanner Catalog # 20-526 www.radioshack.comSM IMPORTANT! If an icon appears at the end of a paragraph, go to the box on that page. And when you click on the file or icon it will count as a download. If you can't find a manual please do not contact us, all the manuals we have are online. PRO-96 Owners manual.zip: 495 Kbytes: PRO-96 Preloaded Data Addendum.zip: 488 Kbytes. This is all the manuals for Radio Shack. If you want to see manuals from other manufactories.

From The RadioReference Wiki

Easier to Read Pro 97/2055 Manual-Printed Manual: Easier to Read BCD996T/UBCD996T Manual-Printed Manual-Planned: Easier to Read Pro Manual-Printed Manual-Planned: Easier to Read UBC3500XLT Manual-Printed Manual: Easier to Read Pro 94 Manual-Printed Manual: Easier to Read BCT-15 Manual-Printed Manual-Planned. OWNER’S MANUAL — Please read before using this equipment. PRO-96 Digital Trunking Scanner Catalog # 20-526 www.radioshack.comSM IMPORTANT! Radio Shack Pro-96 Step-by-Step EDACS Programming Guide Written by David Cabatu, AH7E INTRODUCTION This white page will give you step-by-step instructions to program the Radio Shack Pro-96 scanner to properly receive Ericsson.

The Pro-96 is discontinued and was manufactured for Radio Shack by GRE America Inc.

The Radio Shack is a Digital Trunk Tracking scanner which boasts the ability to track APCO 25 digital trunking systems, in addition to following Motorola type I/II systems and EDACS trunking systems.

NOTE Computer Control of GRE/RS radios is not possible due to firmware limitations.

  • 1General Specifications

General Specifications

Features

  • Can be updated to support Rebanding? YES via a custom table
    • See Section 7.2 of the Rebanding article for the software links
  • 500 channels - 10 banks +Virtual Memory - Allows up to 5500 channels (11 folders)
  • 25-54, 108-174, 216-225, 406-512, 806-960, 1240-1300MHz range
  • Scan rate 60 cps
  • 5, 6.25, 7.5, 12.5kHz steps
  • TCXO for frequency stability (?)
  • Digital AGC
  • Adaptive digital tracking (ADT)
  • Digital signal processing (DSP)
  • CTCSS/DCS abilities
  • 12-character alpha-tagging
  • 5 ID lists, 30 IDs per list, 150 IDs per bank
  • L/O ID in 'open' mode
  • ID delay
  • Motorola Control Channel Only trunking
  • Backlit keypad
  • Preloaded with the most popular radio systems in the country
  • 6 search ranges/ 1 user definable search range
  • Search 'seek' feature
  • SAME weather alert/priority
  • 1 Priority channel
  • Zeromatic search tuning
  • Per channel or global attenuator
  • Computer Programming (not computer control)
  • 4 AA alkaline/Ni-Cad batteries
  • A cloning cable may be fabricated using 2 1/8 inch mono jacks and shielded cable
Manual

RR System Compatibility

This scanner is compatible with the following Trunking System Types and System Voices used in the RadioReference Database, of course you must verify that the scanner will cover the appropriate frequency range:

  • System Types:
    • Motorola Type I
    • Motorola Type II
    • Motorola Type IIi Hybrid
    • Motorola Type II Smartnet
    • Motorola Type II Smartzone
    • Motorola Type II Smartzone Omnilink
    • EDACS Standard (Wide)
    • EDACS Standard Networked
    • Project 25 Standard
  • System Voices:
    • Analog
    • Analog and APCO-25 Common Air Interface
    • APCO-25 Common Air Interface Exclusive

Modifications

Volume Repair

PART #: 10983344 Pot Assy, W/Switch Volume 8.75

Reviews and User Opinions

Related Pages

Wiki links

Pro 96 Manual Download Windows 7

  • Compare the Pro-96 to other digital models


RadioReference Links


Support Pages - 1.2, 1.4 DSP Firmware and manuals

Supporting Software

  • ARC96
    • See the Radio Shack Scanner Programming Software Support article for instructions on installation and registering the software
  • Win96 page in the wiki
Other Distributors

Yahoo Groups and Message Boards (software and receiver support)

Pro-96 Scanners for Sale


Return to Radio Shack Scanners

Retrieved from 'https://wiki.radioreference.com/index.php?title=Pro-96&oldid=246330'

From The RadioReference Wiki

I got the Pro-96 (or the Pro-2096) scanner. I want to change the programming and I dont know how to do it

Newcomers often find programming a scanner to be a daunting task. This article links to several resources to help you get started. Note that anything in blue is a link.

The Nuts and Bolts

  • If you're a newcomer, you've probably already discovered that there's a huge amount of terms that seem unfamiliar to you. Our Glossary has lots of these terms, along with definitions. Just click on the term you wish to view.
  • When looking at frequencies in our database, float your mouse over the column header, and you should get a balloon with a brief description of the terms and abbreviations that are used there.
  • The biggest hurdle for many is the concept of trunking. Our Trunking Basics article will get you started, as well as this PDF file written by UPMan. Note that you will need Adobe Acrobat or a compatible reader (such as Foxit) to read it.
  • These scanners can't be upgraded for any of the newer protocols that are appearing; these include Project 25 Phase II, DMR, MOTOTRBO, EDACS Provoice and NXDN


Manual Programming

  • If you want to program these radios manually, these shortcuts will help


Owners Manuals and FAQs

  • PRO-96 FAQ
    • Answers to common questions such as can these radios be rebanded, Phase II and 380/700 Mhz trunking support can be found here
  • The owner's manual for the Pro-96 can be downloaded from here
Pro

Pro 96 Scanner

  • The owner's manual for the Pro-2096 can be downloaded from here

Pro 96 Manual Download Windows 10


Software, Data and USB cables

  • There are 2 applications that are designed to work with these scanners
  • You will need a USB-serial converter to connect the PC and scanner. With RS gone, the programming cable harder to find. See the Aftermarket Cables section of the Connecting scanners via USB article.
  • You will also need data, as the V folders as supplied are very out of date. If you purchase a premium subscription you can download data from our database. Alternately you can go to your state's forum and ask for a file. Be specific as to what software you are using, as not all formats are compatible with one another.
Retrieved from 'https://wiki.radioreference.com/index.php?title=Getting_Started_with_your_PRO-96_or_PRO-2096&oldid=261384'